Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38504457

RESUMO

INTRODUCTION: Labor induction rates have increased over the last decades, and in many high-income countries, more than one in four labors are induced. Outpatient management of labor induction has been suggested in low-risk pregnancies to improve women's birth experiences while also promoting a more efficient use of healthcare resources. The primary aim of this paper was to assess the proportion of women in a historical cohort that would have been eligible for outpatient labor induction with oral misoprostol. Second, we wanted to report safety outcomes and assess efficacy outcomes for mothers and infants in pregnancies that met the criteria for outpatient care. MATERIAL AND METHODS: Criteria for outpatient labor induction with oral misoprostol were applied to a historical cohort of women with induction of labor at two Norwegian tertiary hospitals in the period January 1, through July 31, 2021. The criteria included low-risk women with an unscarred uterus expecting a healthy, singleton baby in cephalic position at term. The primary outcome was the proportion of women eligible for outpatient labor induction. Secondary outcomes included reasons for ineligibility and, for eligible women, safety and efficacy outcomes. RESULTS: Overall, 29.7% of the 1320 women who underwent labor induction in a singleton term pregnancy met the criteria for outpatient labor induction. We identified two serious adverse events that potentially could have occurred outside the hospital if the women had received outpatient care. The mean duration from initiation of labor induction to administration of the last misoprostol was 22.4 h. One in 14 multiparous women gave birth within 3 h after the last misoprostol dose. CONCLUSIONS: In this historical cohort, three in ten women met the criteria for outpatient management of labor induction with oral misoprostol. Serious adverse events were rare. The average time span from the initiation of labor induction to the last misoprostol was nearly 24 h. This suggests a potential for low-risk women with an induced labor to spend a substantial period of time at home before labor onset. However, larger studies testing or evaluating labor induction with oral misoprostol as an outpatient procedure are needed to draw conclusions.

2.
J Chromatogr A ; 1602: 117-123, 2019 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-31229251

RESUMO

The use of miniaturized systems with the possibility for automation has become increasingly popular in the field of bioanalysis. As a new approach to liquid phase microextraction in the 96-well format, parallel artificial liquid membrane extraction (PALME) was introduced in 2013. In the present work, the reliability of the quantitative data obtained with PALME was thoroughly evaluated. Amitriptyline, nortriptyline, quetiapine, venlafaxine, o-desmethylvenlafaxine, and fluoxetine were selected as model analytes. The analytes were extracted under non-exhaustive conditions from human plasma samples and the extracts were analyzed directly by LC-MS/MS. Accuracy was within ±15% and precision was <15% when the QC samples were prepared in both pooled plasma and in plasma from multiple sources. Accuracy and precision was superior when stable isotopically labelled (SIL) internal standards were used, as compared to structural analogue internal standards in the plasma samples from multiple sources. SIL internal standards are therefore recommended as the first choice. Assessment of accuracy and precision was also carried out with four different operators performing the extraction procedure, providing accuracy within ±15% and precision <15%. The extraction recoveries were in the range from 48 to 85 %, and non-exhaustive extraction of the analytes did not affect the accuracy and precision of the method. With the method described, up to 96 samples can be extracted with a total extraction time of 60 min and with a total consumption of organic solvent less than 0.4 mL for the whole wellplate. PALME is therefore a new approach to high-throughput sample preparation, providing accurate quantification, along with simple workflow, low consumption of organic solvent, and extensive sample clean-up.


Assuntos
Microextração em Fase Líquida/métodos , Preparações Farmacêuticas/sangue , Calibragem , Cromatografia Líquida , Humanos , Marcação por Isótopo , Membranas Artificiais , Controle de Qualidade , Padrões de Referência , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem
3.
Anal Chim Acta ; 1009: 56-64, 2018 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-29422132

RESUMO

In this paper, parallel artificial liquid membrane extraction (PALME) was used for the first time to clean-up dried blood spots (DBS) prior to ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). Fundamental studies exploring amongst others desorption from the DBS in alkaline or acidic aqueous conditions, total extraction time and absolute recoveries were executed. Desorption and PALME were performed using a set of two 96-well plates, one of them housing the sample and the other comprising the supported liquid membrane (SLM) and the acceptor solution. In one procedure, amitriptyline and quetiapine (basic model analytes) were desorbed from the DBS using 250 µL of 10 mM sodium hydroxide solution (aqueous), and subsequently extracted through the SLM consisting of 4 µL of 1% trioctylamine in dodecyl acetate, and further into an acceptor solution consisting of 50 µL of 20 mM formic acid. In a second procedure, ketoprofen, fenoprofen, flurbiprofen, and ibuprofen (acidic model analytes) were desorbed from the DBS into 20 mM formic acid, extracted through an SLM with dihexyl ether, and further into an acceptor solution of 25 mM ammonia. Within 60 min of PALME, both basic and acidic model analytes were effectively desorbed from the DBS and extracted into the acceptor solution, which was injected directly into the analytical instrument. Recoveries between 63 and 85% for the six model analytes were obtained. PALME provided excellent clean-up from the DBS samples, and acceptor solutions were free from phospholipids. Linearity was obtained with r2 > 0.99 for five of the six analytes. Accuracy, precision and UHPLC-MS/MS matrix effects were in accordance with the European Medicines Agency (EMA) guideline. Based on these experiments, PALME shows great potential for future processing of DBS in a short and simple way, and with the presented setup, up to 96 DBS can be processed within a total extraction time of 60 min.


Assuntos
Teste em Amostras de Sangue Seco , Extração Líquido-Líquido , Amitriptilina/sangue , Cromatografia Líquida de Alta Pressão , Fenoprofeno/sangue , Flurbiprofeno/sangue , Voluntários Saudáveis , Humanos , Ibuprofeno/sangue , Cetoprofeno/sangue , Membranas Artificiais , Fumarato de Quetiapina/sangue , Espectrometria de Massas em Tandem
4.
Bioanalysis ; 10(6): 385-395, 2018 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-29451001

RESUMO

AIM: Liquid-liquid extraction is widely used in therapeutic drug monitoring of antipsychotics, but difficulties in automation of the technique can result in long operational time. In this paper, parallel artificial liquid membrane extraction was used for extraction of serotonin- and serotonin-norepinephrine reuptake inhibitors from human plasma, and an approach to automate the technique was investigated. RESULTS: Eight model analytes were extracted from 125 µl human plasma with recoveries in the range 72-111% (relative standard deviation [RSD] ≤12.8%). A semiautomated pipettor was successfully utilized in the procedure, reducing the manual handling time. Real patient samples were analyzed with satisfying accuracy. CONCLUSION: A semiautomated extraction of serotonin-and serotonin-norepinephrine reuptake inhibitors by parallel artificial liquid membrane extraction extraction was successfully performed.


Assuntos
Antipsicóticos/farmacologia , Monitoramento de Medicamentos/métodos , Extração Líquido-Líquido/métodos , Humanos
5.
Artigo em Inglês | MEDLINE | ID: mdl-27650942

RESUMO

The new microextraction technique named parallel artificial liquid membrane extraction (PALME) was introduced as an alternative approach to liquid-liquid extraction of charged analytes from aqueous samples. The concept is based on extraction of analytes across a supported liquid membrane sustained in the pores of a thin polymeric membrane, a well-known extraction principle also used in hollow fiber liquid-phase microextraction (HF-LPME). However, the new PALME technique offers a more user-friendly setup in which the supported liquid membrane is incorporated in a 96 well plate system. Thus, high-throughput is achievable, in addition to the green chemistry offered by using PALME. The consumption of organic solvent is minimized to 3-5µL per sample. With a sample volume of 250µL and acceptor solution volume of 50µL, a maximal enrichment factor of five is achievable. Based on these parameters, a new method for extraction of polar basic drugs was developed in the present work. The basic drugs hydralazine, ephedrine, metaraminol, salbutamol, and cimetidine were used as model analytes, and were extracted from alkalized human plasma into an aqueous solution via the supported liquid membrane. The extraction was promoted by a carrier dissolved in the membrane, creating a temporary ion-pair complex between the hydrophilic drug and the carrier. As the model analytes were extracted directly into an aqueous solution, there was no need for evaporation of the extract before injection into LC-MS. Hence, the sample preparation is performed in one step. With optimized conditions, the extraction recoveries were in the range 50-89% from human plasma after 45min extraction. The data from the method evaluation were satisfactory and in line with current guidelines, and revealed an extraction method with substantial potential for high throughput bioanalysis of polar basic drugs.


Assuntos
Cromatografia Líquida/métodos , Extração Líquido-Líquido/métodos , Espectrometria de Massas/métodos , Membranas Artificiais , Preparações Farmacêuticas/sangue , Preparações Farmacêuticas/isolamento & purificação , Humanos , Limite de Detecção , Modelos Lineares , Preparações Farmacêuticas/química , Reprodutibilidade dos Testes
6.
J Pharm Biomed Anal ; 129: 229-236, 2016 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-27433988

RESUMO

Generic Parallel Artificial Liquid Membrane Extraction (PALME) methods for non-polar basic and non-polar acidic drugs from human plasma were investigated with respect to phospholipid removal. In both cases, extractions in 96-well format were performed from plasma (125µL), through 4µL organic solvent used as supported liquid membranes (SLMs), and into 50µL aqueous acceptor solutions. The acceptor solutions were subsequently analysed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) using in-source fragmentation and monitoring the m/z 184→184 transition for investigation of phosphatidylcholines (PC), sphingomyelins (SM), and lysophosphatidylcholines (Lyso-PC). In both generic methods, no phospholipids were detected in the acceptor solutions. Thus, PALME appeared to be highly efficient for phospholipid removal. To further support this, qualitative (post-column infusion) and quantitative matrix effects were investigated with fluoxetine, fluvoxamine, and quetiapine as model analytes. No signs of matrix effects were observed. Finally, PALME was evaluated for the aforementioned drug substances, and data were in accordance with European Medicines Agency (EMA) guidelines.


Assuntos
Preparações Farmacêuticas/química , Fosfolipídeos/química , Plasma/química , Tecnologia Farmacêutica/métodos , Cromatografia Líquida/métodos , Fluoxetina/química , Fluvoxamina/química , Humanos , Lisofosfatidilcolinas/química , Membranas Artificiais , Fosfatidilcolinas/química , Fumarato de Quetiapina/química , Esfingomielinas/química , Espectrometria de Massas em Tandem/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...